Dimmable Electronic CFL Ballast

Specifications

Parameter

Ballast Factor (BF) Variable (0.05 - 1.0), field programmable
Power Factor (PF) > 0.99
Total Harmonic Distortion (THD) < 10%
Lamp Current Crest Factor (CF) < 1.7
Light Dimming Range 100% - 5%
Lamp Life 100,000 on/off cycles
Lamp Starting Programmed Rapid Start (Pre-Heat Time = 1.5 Seconds)
Operating Frequency 42 kHz - 100 kHz
Light Output Variation Constant light output (± 1%)
for line voltage variation of ± 10%
Ambient Operating Temperature 10 °C - 60 °C (50 °F - 140 °F)
Lamp Start Temperature (Min.) 10 °C (50 °F)
Ballast Case Temperature (Max.) 75 °C (167 °F)
Sound Rating Inaudible in a 27dBa ambient
Maximum Inrush Current 7.0 A
Class 1 to Class 2 Isolation 2.0 kV
Standby Power 1.5 W/2.0W (120V/277V)
Communication Interface DALI (<30 V)

Standards

  • UL 935
  • ANSI C82.11 High Frequency Ballast Standard
  • ANSI C62.41 Cat. A Surge Protection (up to 4.0 kV)
  • Class P Thermal Protection
  • Manufactured in a ISO 9001 certified factory
  • Lamp end of life protection circuitry